A frekvenciaváltók használatának főbb pontjai

The braking unit supplier reminds you that in order to ensure the safe and stable operation of the frequency converter, it is very important to meet the allowable operating environment requirements of the frequency converter. In summary, do not let the operating environment of the frequency converter exceed the allowable temperature, and pay attention to the ventilation performance of the frequency converter cabinet. If the ambient temperature of the frequency converter is too high, it will reduce the electrical insulation and corrode the metal parts. Dehumidification should be considered to prevent condensation of the frequency converter. When using a frequency converter under safe operating conditions, the following points should be mastered:

1. The frequency converter must be reliably grounded to ensure safe operation and effectively suppress electromagnetic interference.

2. Frequency converters are not suitable for conducting voltage withstand tests and insulation resistance tests. When doing it, a 500V insulation resistance meter should be used for measurement, and the number of shake tests should be minimized as much as possible. Before insulation, all external main power and control circuits should be disconnected and the main circuit should be short circuited; The ground insulation should be ensured to be above 5 megohms.

3. When controlling the motor with a frequency converter, it is necessary to ensure that the motor has good ventilation conditions, and external ventilation and cooling measures should be taken if necessary.

4. When using a frequency converter with multiple motors, in addition to ensuring that the total current of the motors is less than the rated current of the frequency converter, it is also necessary to calculate the impact of the starting current of at least one motor to avoid overcurrent tripping of the frequency converter.

5. Capacitor compensation devices should not be connected to the output side of the frequency converter to prevent overcurrent protection tripping and even damage to the frequency converter.

6. The operation and stop of the motor driven by the frequency converter cannot be directly operated using low-voltage circuit breakers or AC contactors. It should be operated through the control terminals of the frequency converter, otherwise it may cause the frequency converter to lose control and cause accidents.

7. Avoid driving motors with variable frequency drives that do not match their capacity. A small motor capacity will affect the effective torque output, while a large capacity will increase the harmonic capacity.

8. When the driven motor has a brake, the frequency converter should operate in a free stop mode, and the action signal of the brake must be issued after the frequency converter sends a stop command.

9. When using a frequency converter to drive explosion-proof motors, due to the lack of explosion-proof performance, the frequency converter should be placed outside of hazardous areas.

10. Amikor frekvenciaváltót használnak egy reduktor meghajtására, annak felhasználási tartományát a fogaskerék forgó részeinek kenési módja korlátozza. Kenőolajjal történő kenés esetén nincsenek korlátozások az alacsony fordulatszám-tartományban; a névleges fordulatszám feletti nagy fordulatszám-tartományban elegendő kenőolaj-ellátás előfordulhat, ezért a maximálisan megengedett fordulatszámot kell figyelembe venni.

11. A frekvenciaváltó használata előtt különös figyelmet kell fordítani a felhasználói kézikönyv figyelmes elolvasására. A frekvenciaváltó bemeneti és kimeneti fő tápellátása nem cserélhető fel, és a "COM" és a "GND" nem keverhető össze. Különös figyelmet kell fordítani a következőkre: Az RFI-szűrőket nem szabad semleges, földeletlen elektromos hálózatokban (IT-rendszerek, lebegő elektromos hálózatok) használni, különben a tápegység rövidzárlatot okozhat a szűrőkondenzátoron keresztül a földhöz, ami veszélyt vagy a frekvenciaváltó károsodását okozhatja.

12. Próbaüzemeltetés során először terhelés nélkül, majd könnyű terheléssel, végül teljes terheléssel kell járatni.

13. A frekvenciaváltó működése közben lehetőség van a berendezésen kívülről vizuálisan ellenőrizni az üzemi körülményeket az esetleges rendellenességek szempontjából, és a kezelőpanelen keresztül ellenőrizni a frekvenciaváltó üzemi paramétereit a frekvenciaváltóval és a motorral kapcsolatos problémák gyors észlelése érdekében.

14. A frekvenciaváltót rendszeresen tisztítani és portalanítani kell a belső tisztaság és a légcsatornák simaságának megőrzése érdekében.

15. Tartsa tisztán és szárazon a frekvenciaváltó környezetét, és ne helyezzen a közelébe semmilyen oda nem tartozó tárgyat.

16. A frekvenciaváltó telepítése és karbantartása után gondosan ellenőrizze a hiányzó csavarokat és vezetékfejeket, hogy megakadályozza a kis fémtárgyak beesését a frekvenciaváltóba, és belső áramköri rövidzárlatot okozó hibákat.